SIMATIC ET 200S SIMATIC ET 200S COMPACT The SIMATIC ET 200S is a distributed I/O system to degree of protection IP20. It comprises: Its extensive module spectrum and system-wide handling of configuring, installing and programming tasks make the ET 200S well-suited as a universal I/O system. The discretely modular design ensures fast and optimum adaptation to system requirements: Even when requirements change frequently, replacement or combining of different I/O modules can noticeably reduce setting-up times. With a data signaling rate of up to 12 Mbit/s on the PROFIBUS DP and extremely powerful internal data transport capabilities, the ET 200S is also eminently suitable for extremely time-critical applications. Two different variants are available for integrating safety technology with ET 200S. The design of the ET 200S allows it to be used in areas subject to increased mechanical stress. The system characteristics meet high plant availability requirements. The following components are available for the ET 200S distributed I/O system: Interface module IM 151 for connecting the PROFIBUS DP (IM 151-1, IM 151-7) or PROFINET (IM 151-3, IM 151-8) to the ET 200S Station. The terminating module is included in the scope of delivery of the interface modules. IM 151-1 BASIC for connecting up to 12 I/O modules (all types, except for PROFIsafe and spare modules) to PROFIBUS DP; RS485 Sub-D connector is used for connecting to the bus IM 151-1 COMPACT with integral digital inputs and outputs. The IM 151-1 COMPACT can be expanded with up to 12 I/O modules (all types, except for PROFIsafe and spare modules); RS485 Sub-D connector is used for connecting to PROFIBUS DP. The IM 151-1 COMPACT is available in two variants: IM 151-1 STANDARD and IM 151-1 FO STANDARD for connecting up to 63 I/O modules (all types, except for PROFIsafe) to PROFIBUS DP; RS485 Sub-D connector or integral fiber-optic connection can be used alternatively for connecting to the bus IM 151-1 HIGH-FEATURE for connecting up to 63 I/O modules (all types, except for isochronous mode) to PROFIBUS DP; RS485 Sub-D connector is used for connecting to the bus IM 151-3 PN for the connection of max. 63 I/O modules (all types except PROFIsafe and spare modules) to PROFINET I/O-Controller; bus connection via RJ45 plug IM 151-7/CPU or IM 151-7/CPU FO as above, but with integral CPU 314 of SIMATIC S7-300 for preprocessing the process data; PROFIBUS DP connector is used for connection to the bus I/O modules Power modules for specific grouping of load and encoder supply voltages and their monitoring Electronic modules for process data exchange Terminal modules support the electrical and mechanical interconnection of the I/O modules and contain the terminals for process wiring. Screw-type terminals, spring-loaded terminals and the non-strip fast connection system "FastConnect" are available. The latter provides time savings of up to 60 % for wiring up. TM-P Terminal modules for power modules TM-E Terminal modules for electronic modules TM-C Terminal modules for IM 151-1 COMPACT TM-C Terminal modules for motor starters and frequency converters Accessories Manuals The manuals for the decentralized I/O system ET 200S can be downloaded in the languages German, English, Chinese, Italian, Spanish or French via Internet (SIMATIC Customer Support, http://www.siemens.com/automation/support ). The manuals are also available on the SIMATIC Manual Collection CD. Sheet of labels DIN A4, preperforated, in various colors, for printing identification labels on laser printers Terminating module Spare part, supplied as standard with IM 151 Shield connection Shield connecting element, shield terminal, ground terminal, 3 x 10 mm copper voltage bus; components for the low-impedance connection of cable shielding at low cost of installation Labels For numbering the terminal modules, preprinted or blank Color-coded labels For individual color-coding of the terminals on the TM-P, TM-C and TM-E terminal modules, different colors are available individually packed Mounting The ET 200S is designed with permanent wiring. In the process, the terminal module is snapped onto a DIN rail (35 x 15 x 7.5 mm) and can be pre-wired and tested without an I/O module. In addition, this design supports the removal and insertion of I/O modules during energization for the replacement of modules in RUN mode and for rapid error locating with regard to the affected module without having to turn off the power (hot swapping). The automatic coding of the I/O modules reliably prevents the risk of injury to persons and/or destruction of modules through accidental mounting of the wrong module. Only a few rules have to be observed when configuring an ET 200S station: Expansion limits The configuration limits for an ET 200S station vary in accordance with the interface module used. The following parameters can limit the configuration scope: Configuring rules Terminal modules Various terminal modules are available for a very wide range of requirements. The TM-P, TM-C and TM-E are also available with screw-type or spring-loaded terminals. All TM-P and TM-E of 15 mm width can be supplied alternatively with the no-strip fast connection terminals "FastConnect". Depending on the selected combination of I/O and terminal module, differing terminal assignments result. A universal terminal module TM-E15x26-A1 is available for universal applications with electronic modules. This supports all the connection types including 3-wire connection for 4-channel digital modules with electronic modules of 15 mm width. The precise pinouts for the different combinations are listed in the manual. Additional information is available in the Internet under: http://www4.ad.siemens.de/view/cs/com/1144348 Mode of operation Via PROFIBUS DP or PROFINET a central controller can access the I/O modules of the ET 200S in the same way as central I/O modules. Communication is handled entirely by the master interface (in the central controller) and in the IM 151. Interference-free internal data transport is using shielded leads. Comprehensive, channel-specific and easy-to-program diagnostics with clear text messages allow for the localization and correction of plant errors in the shortest time and significantly increases availability. Configuration, parameterization and diagnostics The configuration and parameterization of the ET 200S is achieved using STEP 7 or the configuration tool of the PROFIBUS master or PROFINET controller used. During plant configuration it should be assured that the selected PROFIBUS DP-master has sufficient resources available for the DP network. The ET 200S and its I/O modules provide the user with complete and channel-specific diagnostic information. For example, integrated, electronic short-circuit protection for the sensor power supply of digital HF input modules reduces troubleshooting to a minimum, thus increasing the availability of the plant. A diagnostic package with function blocks for SIMATIC S7-CPU and images for various OPs is provided at no charge for the simple evaluation of diagnostic information. General technical specifications Degree of protection IP20 Ambient temperature 0 … 60 °C Vibration resistance 2 g continuously, 5 g temporarily (motor starter max. 2 g) Maximum configuration (none of the limits listed below must be exceeded) Number of modules per IM 151, max. IM 151-1 BASIC: Up to 12 modules IM 151-1 COMPACT: Up to 12 modules IM 151-1 STANDARD: Up to 63 modules IM 151-1 HIGH-FEATURE: Up to 63 modules IM 151-7 CPU: Up to 63 modules IM 151-3 PN: Up to 63 modules Line width, max. IM 151-1 BASIC: Up to 2 m IM 151-1 COMPACT: Up to 2 m IM 151-1 STANDARD: Up to 2 m IM 151-1 HIGH-FEATURE: Up to 2 m IM 151-7 CPU: Up to 1 m IM 151-3 PN: Up to 2 m User data length Depending on the number and type of connected modules IM 151-1 BASIC: Up to 88 byte for inputs and outputs IM 151-1 COMPACT: Up to 100 byte for inputs and outputs IM 151-1 STANDARD: Up to 244 byte for inputs and outputs IM 151-1 HIGH-FEATURE: Up to 244 byte for inputs and outputs IM 151-7 CPU: Not relevant IM 151-3 PN: 256 byte Parameter length Depending on the number and type of connected modules IM 151-1 BASIC: 198 byte IM 151-1 COMPACT: 218 byte IM 151-1 STANDARD: Up to 244 byte IM 151-1 HIGH-FEATURE: Up to 244 byte IM 151-7 CPU: Not relevant IM 151-3 PN: Not relevant Requirements of the DP master system PROFIBUS DP master In accordance with EN 50170 Parameter length >32 byte, depending on the number and type of connected modules User data length Depending on the number and type of connected modules Diagnostics length 17 … 64 byte (adjustable) Standards and approvals PROFIBUS EN 50170, Volume 2 IEC 1131 IEC 1131, Part 2 UL acc. to UL508 standard, File No. E 116536/E 75310 (AC modules) C-Tick AS/NZS 2064 (Class A) CSA acc. to standard C22.2 No. 142, File No. LR 48323/LR 44226 (AC modules) cULus for hazardous locations acc. to UL 508 standard, File No. E 116536 acc. to hazardous locations UL 1604, File no. E 222109 acc. to CSA C22.2 standard, No. 142 FM Standard Class No. 3611, Class I, Division 2, Group A, B, C, D, Class I, Zone 2, Group IIC (without motor starter and frequency converter) Shipbuilding American Bureau of Shipping Bureau Veritas Det Norske Veritas Germanischer Lloyd Lloyds Register of Shipping Nippon Kaiji Kyokai (without motor starters and frequency converters) Ex approval Cat. 3 (for Zone 2 acc. to ATEX–100a) EN 50021 (without frequency converters)
ET200S
With SIMATIC ET 200 a wide range of distributed I/O systems is available – for solutions in the control cabinet or without a control cabinet directly at the machine, as well as for applications in hazardous areas. The modular design makes it possible to scale and expand the ET 200 systems simply and in small stages. Already integrated add-on modules reduce costs, and at the same time offer a widely diverse range of possible applications. You can choose from many different combination options: Digital and analog inputs/outputs, intelligent modules with CPU functionality, safety systems, motor starters, pneumatic devices, frequency converters, as well as various different technology modules (e.g. for counting, positioning).